Send Email
Send SMS
Search
Plenum Tech Private Limited


Syringe Pump

Our range of products include syringe pump - crest, syringe pump - zeta, syringe pump - zion and syringe pump - zion plus.

Syringe Pump - Crest

REQUEST CALLBACK

Syringe Pump - Crest
Ask for Price

Thanks for Contacting Us.

Product Details:
Minimum Order Quantity5 Unit
Number of Syringes1.0
Syringe Size10 ml-10 ml, 10 ml-60 ml, 60 ml-100 ml, 10 ml-10 ml, 10 ml-60 ml, 60 ml-100 ml
Dimension 130 mm (W) x 183mm (L) x 115mm (H)
Power Source 110/220 VCA (+/-20%), 50/60 Hz, 12 VA
Operating Temp 05 deg - 40 deg C
Weight 1.8 Kgs
Display Size & Type 135mm x 21mm EBTN LCD Display
Relative Humidity15 to 90% (no condensation)
Atmospheric Pressure 70 to 106 Kpa
Battery4.8 Rechargeable NiMh Capacity minimum 4hrs @ 5ml/hr Recharging time 16 hrs

Physical Specification:
  • Product Type: Front Loading Syringe Infusion pump
  • Pumping Mechanism: Lead Screw Mechanism
  • Parameters Diplayed: Syringe size, Syringe Brand, Set Flow Rate Infused Volume, Occlusion level, Battery life Alarms & Indicators
  • Keypad: Capacitive touch screen keypad
  • Fixation: Allows Horizontal and Vertical Mounting
  • Stackability: For interlocking of two or more units

Basic Infusion Controls:
  • Syringe Capacity: 5,10,20,30,50/60 and 100 CC Auto Detection
  • Syringe Brands: Dispovan, BBraun Perfusor, BD Precise, Platipak Romson & Sisco (Provision add 12 more brands)
  • Flow Rate: 0.1 to 1200 ml/hr (increment in step of 0.1ml/hr Facility for Online titration
  • Purge: Upto 1200 ml/hr
  • Bolus Rate: Upto 1200 ml/hr
  • Bolus Volume: Settable (pre-set)
  • KVO/KOR: 1% of the set rate or minimum of 0.1 ml/hr
  • Mechanical Accuracy: +/- 1%
  • Overall Accuracy: +/- 2% (Measured Time > 1Hr, min 0.2 ml excluding syringe tolerance)
  • (Measured as per IEC 60601-2-24)

Pressure Management:
  • Pressure Limits: Low 0.4 kg/cm2 (300 mmHg), Mid 0.8 kg/cm2 (600 mmHg), High 1.2 kg/cm2 (900 mmHg)
  • Tolerance: +/- 20%
  • Anti-bolus System: Reduces significantly bolus after occusion release (measured as per IEC 60601-2-24)

Pre Alarms/Alarms/Security Features:
  • Alarms: All the alarms are expressed by means of flashing message/symbol on the display and sound beep
  • Syringe Detection: Syringe Dislocated, Drive Disengaged, Patient Line Disconnection, Plunger Disengaged
  • Device Control: No Mains, Battery pre-alarm & Alarm, Idle Technical Malfunction
  • Infusion Control: Occlusion, Infusion End pre-alarm & Alarm KVO/KOR, Syringe Empty

Standard Accessories:
  • Unit with pole clamp, power cord & operating manual

Optional Feature:
  • Power Source: External Power 12 VDC converter (For Ambulatory supply)
  • Battery Life: Upgradable to 5 hr / 10 hr @ 5 ml/hr
  • Stackability: Multiple inputs AC cord for up to 8 pumps
  • Communication: RS232 port
  • Other: Nurse call attachment

Quality Standard:
  • Electrical Safety: Class II, Type CF

Additional Information:

  • Item Code: CREST
  • Send Business Enquiry

    View PDF

    Syringe Pump - Zeta

    REQUEST CALLBACK

    Syringe Pump - Zeta
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity5 Unit
    ApplicationDrug Delivery
    Number of Syringes1.0
    Syringe Size5 ml - 100 ml, 10 ml-10 ml, 10 ml-60 ml, 60 ml-100 ml
    Dimension130mm (W) x 183mm (L) x 115mm (H)
    Weight1.8 Kgs
    Display Size & Type66mm x 33mmm Graphic LCD Monochrome
    Power Source110/220 VCA (+/- 20%), 50/60 Hz, 12 VA
    Battery4.8 Rechargeable NiMh Capacity minimum 4 hrs @ 5 ml/hrRechargingg time 16 hrs
    Operating Temp.05 to 40 deg C
    Atmospheric Pressure70 to 106 Kpa
    Relative Humidity15 o 90% (no condensation)

    Product Specification:
    • Product Type: Front Loading Syringe Infusion Pump
    • Pumping Mechanism: Lead Screw Mechanism
    • Parameters Displayed: Occlusion Level, Syringe Size, Syringe Brand, Drug Name, Set Flow Rate, Infused Volume, Battery Life, Alarms & Indicators
    • Keypad: Capacitive Touch Screen Keypad
    • Fixation: Allows Horizontal & Vertical Mounting
    • Stackability: For Interlocking of two or more units
    • Battery Status: Display in Bars OR hrs, and min.
    • Power Saver: Auto adjust display brightness to save battery

    Basic Infusion Controls:
    • Syringe Capacity: 5,10,20,30,50/60 and 100 CC Auto Detection
    • Syringe Brands: Dispovan, BBRaun Perfusor, BD Precise, Plastipak Romson & Sisco (Provision to add 13 more brands)
    • Flow Rate: 0.1 to 2000 ml/hr (increment in step of 0.1 ml/hr) Facility for online titration
    • Purge: Upto 2000 ml/hr
    • Priming: 3Modes: Mandatory/ Non Mandatory/ Advised Rate: Upto 2000 ml/hr
    • Bolus Type: Auto & Manual
    • Bolus Rate: Upto 2000 ml/hr
    • Bolus Volume: 0.1 ml to max capacity of syringe (0.1ml incr.)
    • Bolus Indicator: Beep after infusion of every 0.5/1 ml bolus volume
    • Infusion Modes: 1: Rate ml/hr (0.1ml /hr incr., 2. Volume Limit 0.1-999.9 ml (01 ml incr.), 3. Volume /Time 0.1-999.9 ml; 00h01-100h00, 4. Dose Rate, # Dose Unit: mcg/min, mcg/hr, mcg/kg/min mcg/kg/hr mg/min, mg/hr mg/kr/min, mg/kg/hr, # Dilution: X mg/ml or X mg / Y ml, 5. Upgradable to PCA
    • Standby: Programmable form 1 min. to 24 hrs.
    • Drug Labelling: 64 drug name with provision for user add/delete
    • KVO/KOR: Settable from 0.1 to 5 ml/hr Provision to keep it off.
    • Mechanical Accuracy: +/- 1%
    • Overall Accuracy: +/- 2% (Measured time, 1 Hr, min 0.2 ml

    Pressure Management:
    • Pressure Modes: Variable / 3 Pre-set Levels /10 Pre-set Levels From 100 to 900 mmHg, 50 mmHg increment
    • Pressure Limits: Low 0.4 kg/cm2 (300 mmHg)
    • Mid 0.8 kg/cm2 (600 mmHg)
    • High 1.2 kg/cm2 (900 mmHg)
    • Tolerance: +/- 20%
    • DPS: Warns Pressure Variation
    • Pressure Monitoring: Graphic Representation of the pressure limits
    • Anti-bolus System: Reduces significantly bolus after occlusion release

    Pre Alarms/ Alarms/ Security Features:
    • Alarms: All the alarms are expressed by means of flashing message/symbol on the display and sound beep
    • Syringe detection: Syringe Dislocated, Drive Disengaged, Patient Line Disconnection, Plunger Disengaged
    • Device Control: No Mains, Battery Pre-alarm & Alarm, Idle, Technical Malfunction, Unconfirmed Programming Preventive Maintenance
    • Infusion control: Occlusion Pre-alarm & Alarm, Infusion End Pre-alarm & Alarm, KVO/KOR, Syringe Empty
    • Keypad Locking: Restricts Accidental change of the infusion parameters

    Standard Accessories:
    • Unit with pole clamp, power cord & operating manual

    Optional / Upgradable Feature:
    • Power Source: External Power 12 VDC converter (For ambulatory power supply)
    • Battery Life: Upgradable to 5/10 hr @ ml/hr
    • Stackability: Multiple input AC cord to power upto 8 pumps
    • Communication Port: Rs232 port
    • Data Log Event: 500 data log events in real-time Expandable upto 1500 nos.
    • Other: Nurse call attachment
    Send Business Enquiry

    View PDF

    Syringe Pump - Zion

    REQUEST CALLBACK

    Syringe Pump - Zion
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity5 Number
    ApplicationDrug Delivery
    Number of Syringes1.0
    Syringe Size5 ml - 100 ml, 10 ml-10 ml, 10 ml-60 ml, 60 ml-100 ml
    Syringe DetectionAutomatic
    Power Source110/220 VAC (+/-10%), Freq: 50/60Hz, 12 VA, External power 12 VDC by a converter.
    Dimensions135 (H) x 272 (W) x 150 (D) mm
    Weight2.3 Kgs./ Housing: ABS Plastic
    Communication PortRS 232C
    Syringe LoadingFront side
    DisplayGraphic LCD monochrome, size 66 mm x 33 mm ( 128 x 64 pixels)

    Infusion:
    • Flow Rate Range: 0.1 to 1200 ml/hr in normal mode, depending on syringe capacity (0.1 ml/hr increment)
    • Syringe Capacity: 05, 10, 20, 30/35, 50/60 ml
    • Type Of Syringe: Dispovan, BD Precise, Plastipak, Bbraun Perfusor, Romoson ( Capacity to store 20 brands)
    • Priming: Priming Rate: Up to 1200 ml/h depending on syringe size
    • Bolus: Bolus rate: 1 to 1200 ml/hr (1 ml/hr Increment), Bolus volume: 0.1 ml to the max capacity of syringe ( 0.1 ml increment)
    • Infusion Modes: 1] ml/h (0.1 ml/h increments), 2] Volume limit: 0.1-999.9 ml (0.1 ml increments), 3] Volume / time: 0.1-999.9 ml; 00h01- 100h00., 4] Dose rate., # Dose units: mcg, mcg/min, mcg/hr, mcg/kg/min, mcg/kg/hr,mg, mg/min, mg/hr, mg/kg/min, mg/kg/hr, # Dilution setting: X mg/ml or X mg / Y ml.
    • Drug Labelling: Display of the available drug name from the drug library. The user can add or delete drug names up to 64 nos.
    • Accuracy: Mechanical accuracy: ±1%, Overall Accuracy: ±2%,(excluding syringe tolerances)
    • End Of Infusion: (V/T & VL) KVO 1 and KVO 2: from 0.1 to 5 ml/h adjustable and storable, continuous infusion or stop.

    Pressure Management:
    • Pressure Modes: Low:- 0.4 kg/cm2 (300 mmHg), Mid:-0.4 kg/cm2 (600 mmHg), High:-0.4 kg/cm2 (900 mmHg), tolerance +/-20%
    • Anti-Bolus System: Reduces significantly bolus after occlusion release.

    Pre-Alarms/ Alarms/ Security:
    • Pump Status: Red for AC power status and Green for infusion in progress. Idle/ Nonoperative time over. Visibility up to 5 meters. All alarms are expressed by means of flashing messages on LCD, graphics and sound beep.
    • Syringe Position Control: Syringe barrel knob check, Plunger head detection, Anti-siphon system check.
    • Device control: Disengaged driving mechanism alarm, Low battery pre-alarm, Discharged battery alarm, Unconfirmed programming, Technical malfunction alarm, Drive system advance check, Watchdog check.
    • Infusion Control: Occlusion pressure alarm, End of infusion pre-alarm, End of infusion alarm, Syringe empty, KVO, Volume limit pre-alarm, Volume limit alarm, keypad locking.

    Technical Specifications:
    • Battery: 8.4V Rechargeable Ni-Mh, Capacity minimum:10 hrs @ 5 ml/hr, Battery replacement: separate compartment – no need for electrical security testing.
    • Operating Conditions: Temp: 05° to 40°C/ Humidity: 15 to 90 % (no condensation)/ Atmospheric Pressure: 70 to 106 kPa
    • Stackability: Electrical: AC Power cord with multiple inputs to connect max 8 devices on single power socket.
    • Standard Accessories: Unit with IV Pole Mounting Device, Operating Manual
    Send Business Enquiry

    View PDF

    Syringe Pump - Zion Plus

    REQUEST CALLBACK

    Syringe Pump - Zion Plus
    Ask for Price

    Thanks for Contacting Us.

    Product Details:
    Minimum Order Quantity5 Number
    ApplicationDrug Delivery
    Number of Syringes1.0
    DisplayGraphic LCD monochrome, size 66 mm x 33 mm ( 128 x 64 pixels)
    Power Source110/220 VAC (+/-10%), 50/60Hz, 12 VA, external power 12 VDC by a converter.
    Dimensions135 (H) x 272 (W) x 150 (D) mm / Weight: 2.3 Kgs./ Housing: ABS Plastic.
    Communication PortRS 232C
    Stackability (Optional)Up to 3 devices self - stackable on a pole
    Standard AccessoriesUnit with IV Pole Mounting Device, Operating Manual

    Infusion:
    • Flow Rate Range: Up to 2000 ml/hr in normal mode, depending on syringe capacity (0.1 ml/hr increment)
    • Syringe Capacity: 05, 10, 20, 30/35, 50/60 ml
    • Type Of Syringe: Dispovan, BD Precise, Plastipak, BBraun Perfusor, Romoson ( Capacity to store 20 brands)
    • Priming: 3 modes: mandatory, not mandatory, or advised / Rate: Up to 2000 ml/h depending on syringe size
    • Bolus: Bolus rate 1 to 2000 ml/hr (1 ml/hr Increment) . Bolus volume: 0.1 ml to max capacity of syringe (0.1 ml increment)
    • Infusion Modes: 1] ml/h (0.1 ml/h increments), 2] Volume limit: 0.1-999.9 ml (0.1 ml increments), 3] Volume / time: 0.1-999.9 ml; 00h01- 100h00., 4] Dose rate. # Dose units: mcg, mcg/min, mcg/hr, mcg/kg/min, mcg/kg/hr,mg, mg/min, mg/hr, mg/kg/min, mg/kg/hr, U, kU, # Dilution setting: X mg/ml or X mg / Y ml.
    • Drug Labelling: Display of the available drug name from the drug library. The user can add or delete drug names up to 64 nos.
    • Drug Library (Optional): Inbuilt ‘PRUDENT’ Drug library editor for setting normal infusion, bolus, and loading dose parameters. Adjustment of the dilution, default infusion modes, flow rate and bolus limits in ml/h.
    • Accuracy: Mechanical accuracy: ±1%, Overall Accuracy: ±2%,(excluding syringe tolerances)
    • End Of Infusion: (V/T & VL) KVO: from 0.1 to 5 ml/h adjustable and storable, continuous infusion or stop.
    • Pause: Programmable from 1 minute to 24 hours, increments from minute to minute.
    • Data Log Event: 500 datalog events in real time expandable up to 1500 nos.

    Pressure Management:
    • Pressure Modes: 3 modes available: variable or 3 pre-set levels or 10 pre-set levels - from 100 to 900 mmHg, 50 mmHg increment Low:- 0.4 kg/cm2 (300 mmHg), Mid:-0.4 kg/cm2 (600 mmHg), High:-0.4 kg/cm2 (900 mmHg), tolerance +/-20%
    • DPS: The Dynamic Pressure System - DPS - warns of pressure variations. A risk of obstruction or a possible leak in the infusion line can thus be anticipated.
    • Pressure Monitoring: Graphic representation of the pressure limit
    • Anti-Bolus System: Reduces significantly bolus after occlusion release.

    Pre-Alarms/ Alarms/ Security:
    • Pump Status: Red for AC power status and Yellow for infusion in progress. Idle/ Nonoperative time over. Visibility up to 5 meters. All alarms are expressed by means of flashing messages on LCD, graphics and sound beep.
    • Syringe Position Control: Syringe barrel knob check, Plunger head detection, Anti-siphon system check, Flange detection.
    • Device Control: Disengaged driving mechanism alarm, Low battery pre-alarm, Discharged battery alarm, battery capacity, display in hours and minutes, unconfirmed programming, Technical malfunction alarm, Drive system advance check, Watchdog check, Communication
    • connection failure.
    • Infusion Control: Occlusion pressure pre-alarm, Occlusion pressure alarm, End of infusion pre-alarm, End of infusion alarm, Syringe empty, KVO, Volume limit pre-alarm, Volume limit alarm, Keypad locking, Hard and soft flow rate limits.
    • Maintenance: Preventive maintenance warning.

    Technical Specifications:
    • Battery: 8.4V Rechargeable Ni-Mh, Capacity minimum:10 hrs @ 5 ml/hr,Battery replacement: separate compartment – no need for electrical security testing.
    • Operating Conditions: Temp: 05° to 40°C/ Humidity: 15 to 90 % (no condensation)/ Atmospheric Pressure: 70 to 106 kPa
    Send Business Enquiry

    View PDF

     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Plenum Tech Private Limited
    Sujeet Mahajan (Managing Director)
    Plot No. 4 C, Sector 23, Mihan, Non SEZ Area ,
    Nagpur - 441108, Maharashtra, India
    Call Us: 
    Call Response Rate: 93%
    Share Us :
    F G T L



    Home  |   Profile   |  Our Products  |  Site Map  |   Contact Us   |   Mobile Site

    © Plenum Tech Private Limited. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Plenum Tech Private Limited