Plenum'sVolumetric Infusion Pumpis designed to infuse the drug into the vascular system of humans. Each machine is accomplished with microprocessor control of flow rate, volume, timing and activates alarm automatically if there is air in infusion line, infusion rate cannot be maintained or the solution runs out- all provided by a motor - driven finger peristaltic mechanism.
  • Volux

Infusion Pump-Volux

REQUEST CALLBACK

Infusion Pump-Volux
Ask for Price

Thanks for Contacting Us.

Product Price :Get Latest Price

Product Details:
Dimension130mm (W) 113m11(L) x 115mm (H)
Weight2.2 Kgs
Power Source110/220 VCA (+/- 20%), 50/60 Hz, 12 VA
Operating Temp05 to 40 deg C
Atmospheric Pressure70 to 106 Kpa
Battery7.2 Rechargeable NiMh Capacity minimum 3.5 hrs @ 25 ml/hr Recharging time 16 hrs
ModelVOLUX
ApplicationHospital, Clinical Purpose

PRODUCT SPECIFICATION:
  • Product Type: Volumetric Infusion Pump
  • Pumping Mechanism: Liner Peristaltic Pumping System
  • Display Size & Type: 66mm 33mmm Graphic LCD Monochrome
  • Parameters Displayed: Occlusion Level, IV Set Brand, Drug Name, Set Flow Rate, Infused Volume, Battery Life, Alarms & Indicators
  • Keypad: Capacitive Touch Screen Keypad
  • Fixation: Allows Both Horizontal & Vertical Mounting
  • Stackability: For interlocking of two or more units
  • Battery Status: Display in Bars OR hrs. and min.
  • Power Saver: Auto back light off to save battery
  • Relative Humidity: 15 o 90% (no condensation)

Basic Infusion Controls:
  • IV Line Brands: BBRaun, JMS, Romson, polymed (Provision to calibrate 13 more brands)
  • Flow Rate: 0.1 to 1200 ml/hr (increment in step of 0.1 ml/hr) Facility for Online Titration
  • Purge: Upto 1200 ml/hr
  • Priming: 3Modes: Mandatory/ Non Mandatory / Advised Rate: Upto 1200 ml/hr
  • Bolus type: Auto & Manual
  • Bolus Rate: Upto 1200 ml/hr
  • Bolus Volume: 0.1ml to 10ml
  • Bolus Indicator: Beep after infusion of every 0.5/1 ml bolus volume
  • Infusion Modes: 1. Rate ml/hr (0.1ml/hr incr.), 2. Volume Limit 0.1-6500.0 ml (0.1 ml incr.), 3. Volume /Time 0.1-6500.0 ml; 00h01-100h00, 4. Dose Rate, # Dose Unit: mcg/min, mcg/hr, mcg/kg/min mcg/kg/hr mg/min mg/hr, mg/kr/min, mg/kg/hr, # Dilution: X mg/ml or X mg / Y ml
  • Stand by: Programmable form 1 min. to 24 hrs.
  • Drug Labelling: 64 drug name with provision for user add/delete
  • KVO/KOR: Settable from 0.1 to 5 ml/hr Provision to keep it Off.
  • Overall Accuracy : +/-5% (Measured time, 1 Hr, min 0.2 ml) (Measured as per IEC 60601-2-24)

Pressure Management:
  • Pressure Modes: 3 Pre-set Levels
  • Pressure Limits: Low 0.4 kg/cm2 (300 mmHg), Mid 0.8 kg/cm2 (600 mmHg), High 1.2 kg/cm2 (900 mmHg)
  • Pressure Monitoring: Graphic representation of the pressure limit

Security Features:
  • Free-Flow Protection: All integrated sets are clamped automatically by a safety clip to avoid risk of free-flow when the door is opened or the set is disengaged
  • Air Bubble Detection: Ultrasonic Air Bubble Detector to detect air in line Bubble Size 50 ul Accumulated Bubble Size 50-100 ul
  • Keypad Locking: Restricts accidental change of the infusion parameters

Pre Alarms/ Alarms
  • Alarms: Expressed by means of flashing message on the display and sound beep
  • Set Installation: Door Open, Occlusivity Check
  • Device Control: No Mains, Battery Pre-Alarm & Alarm, Idle, Technical Malfunction, Unconfermed Programming, Preventive Maintenance
  • Infusion Control: Occlusion Upstream & Downstream, Infusion End Pre-alarm & Alarm, KVO/KOR, Container Empty
  • Keypad Locking: Restricts accidental change of the infusion parameters

Standard Accessories:
  • Unit with pole clamp, power cord & operating manual

Optional/Upgradable Feature:
  • Power Source: External Power 12 VDC converter (For ambulatory power supply)
  • Battery Life: Upgradable to 5 hr @ 25 ml/hr
  • Stackability: Multiple input AC cord to power upto 8 pumps
  • Communication Port: Rs 232 port
  • Data Log Event: 500 data log events in real time Expandable upto 1500 nos.
  • Other: Nurse call attachement

Quality Standard:
  • Quality Management: ISO 9001: 2008 & ISO 13485: 2003
  • Moisture Protection: IP24 as per IEC 60529 (Splash Proof)
  • Electrical Safety: Class II, Type CF
  • Conformity Standards: IEC 60601-1 & IEC 60601-2-24

Additional Information:

  • Port of Dispatch: Nagpur, Head Office
  • Production Capacity: 300 / month
  • Delivery Time: 8-10 days
  • Send Business Enquiry

    View PDF

     
    X


    Explore More Products

    Contact via E-mail
    Contact via SMS
    Plenum Tech Private Limited
    Sujeet Mahajan (Managing Director)
    Plot No. 4 C, Sector 23, Mihan, Non SEZ Area ,
    Nagpur - 441108, Maharashtra, India
    Call Us: 
    Call Response Rate: 85%
    Share Us :
    F G T L



    Home  |   Profile   |  Our Products  |  Site Map  |   Contact Us   |   Mobile Site

    © Plenum Tech Private Limited. All Rights Reserved (Terms of Use)
    Developed and Managed by IndiaMART InterMESH Limited

    Plenum Tech Private Limited